产品描述
127×127×38MM | ||||||||||||
Model | Bearing | Rated Voltage | Startup Voltage | Current | Power | Speed | Air Flow | Static Pressure | Noise | |||
Part NO. | Function | System | VDC | VDC | A | W | RPM | M3/min | CFM | mmH2O | INH2O | dBA |
12738/H | SLEEVE | 12 | 6.0-13.8 | 2.8 | 33.6 | 5000 | 6.31 | 222.8 | 25.4 | 1 | 60.00 | |
12738/M | 6.0-13.8 | 1.80 | 21.6 | 4000 | 4.98 | 176.1 | 16.7 | 0.66 | 54.0 | |||
12738/L | 6.0-13.8 | 1 | 12 | 3000 | 3.63 | 128.3 | 10.5 | 0.41 | 48.0 | |||
12738/H | BALL | 6.0-13.8 | 2.80 | 33.6 | 5000 | 6.31 | 222.8 | 25.4 | 1.00 | 60.00 | ||
12738.M | 6.0-13.8 | 1.80 | 21.6 | 4000 | 4.98 | 176.1 | 16.7 | 0.66 | 54 | |||
12738/L | 6.0-13.8 | 1 | 12 | 3000 | 3.63 | 128.3 | 10.5 | 0.41 | 48 | |||
12738/H | SLEEVE | 24 | 12.0-27.6 | 1.5 | 36 | 5000 | 6.31 | 222.8 | 25.4 | 1 | 60 | |
12738/M | 12.0-27.6 | 1 | 24 | 4000 | 4.98 | 176.1 | 16.7 | 0.66 | 54 | |||
12738/L | 12.0-27.6 | 0.50 | 12 | 3000 | 3.63 | 128.3 | 10.5 | 0.41 | 48 | |||
12738/H | BALL | 12.0-27.6 | 1.5 | 36 | 5000 | 6.31 | 222.8 | 25.4 | 1 | 60 | ||
12738M | 12.0-27.6 | 1 | 24 | 4000 | 4.98 | 176.1 | 16.7 | 0.66 | 54 | |||
12738/L | 12.0-27.6 | 0.5 | 12 | 3000 | 3.63 | 128.3 | 10.5 | 0.41 | 48 | |||
12738/H | SLEEVE | 48 | 24.0-55.2 | 1 | 48 | 5000 | 6.31 | 222.8 | 25.4 | 1 | 60 | |
12738/M | 24.0-55.2 | 0.6 | 28.8o | 4000 | 4.98 | 176.1 | 16.7 | 0.66 | 54 | |||
12738/L | 24.0-55.2 | 0.35 | 16.8 | 3000 | 3.63 | 128.3 | 10.5 | 0.41 | 48 | |||
12738/H | BALL | 24.0-55.2 | 1 | 48 | 5000 | 6.31 | 222.8 | 25.4 | 1.0o | 60 | ||
12738M | 24.0-55.2 | 0.6 | 28.8o | 4000 | 4.98 | 176.1 | 16.7 | 0.66 | 54 | |||
12738/L | 24.0-55.2 | 0.35 | 16.8 | 3000 | 3.63 | 128.3 | 10.5 | 0.41 | 48 | |||
Electric Strength | 5mA max at 1500VAC for 1 min between lead wire and frame | |||||||||||
Insulation Resistance | 10M ohm between lead wire and frame(DC 500V) | |||||||||||
Life Expectancy(Ball bearing) | 50000hrs min at 40 degree C/L10 relative humidity 65%+/-20% | |||||||||||
Life Expectancy(Hydraulic bearing) | >40000hrs min at 40 degree C/L10 relative humidity 65%+/-20% | |||||||||||
Operation Temperature | -10~75 degree C(+14~167 degree F),normal; -10~90 degree C(+14~194 degree F), specification | |||||||||||
Storage Temperature | Storage Temperature: -40~75 degree C(-40~167 degree F) | |||||||||||
Protection | Motor protection and polarity protection | |||||||||||
Lead wire | UL1571 AWG28,30; UL1007 AWG24,26; UL1061 AWG26 | |||||||||||
Plastic Material | Motor protection and polarity protection |